Tuesday, 14 March 2017

Over voltage Protection Circuit Diagram


When testing a circuit, a source of voltage that is variable and has over voltage shutdown is veiy useful. In this circuit, Rl is adjusted to 1 to 2 V below the eventual shutdown threshold. R2 sets the trip voltage. When this voltage is reached, the circuit shuts the voltage to the circuit under test down. To reset, reduce Rl below trip threshold and depress reset switch SI.

Over voltage Protection Circuit Diagram

Overvoltage Protection Circuit Diagram


Readmore → Over voltage Protection Circuit Diagram

Monday, 2 January 2017

Protection For Your Electrical Appliances


Here is a very low-cost circuit to save your electrically operated appliances, such as tv, tape recorder, refrigerator, and other instruments during sudden tripping and resumption of mains supply. Appliances like refrigerators and air-conditioners are more prone to damage due to such conditions. The simple circuit given here switches off the mains supply to the load as soon as the power trips. The supply can be resumed only by manual intervention. Thus, the supply may be switched on only after it has stabilised.

Protection For Your Electrical Appliances Circuit diagram :
Protection For Your Electrical Appliances Circuit Diagram
Protection For Your Electrical Appliances

The circuit comprises a step-down transformer followed by a full-wave rectifier and smoothing capacitor C1 which acts as a supply source for relay rl1. Initially, when the circuit is switched on, the power supply path to the step-down transformer X1 as well as the load is incomplete, as the relay is in de-energised state. To energise the relay, press switch S1 for a short duration. This completes the path for the supply to transformer X1 as also the load via closed contacts of switch S1. Meanwhile, the supply to relay becomes available and it gets energised to provide a parallel path for the supply to the transformer as well as the load.

If there is any interruption in the power supply, the supply to the transformer is not available and the relay de-energises. Thus, once the supply is interrupted even for a brief period, the relay is de-energised and you have to press switch S1 momentarily (when the supply resumes) to make it available to the load. Very short duration (say, 1 to 5 milliseconds) interruptions or fluctuations will not affect the circuit because of presence of large value capacitor which has to discharge via the relay coil. Thus the circuit provides suitable safety against erratic power supply conditions.


Author : MALAY BANERJEE

Readmore → Protection For Your Electrical Appliances

Monday, 19 December 2016

Feeder Fault Protection Module


Arcing occurs when current breaks through insulation to earth or another phase. For example let , 40MW can be generated. During arc temperatures may reach 20,000°C. There is an explosive pressure wave. Fire breaks out. Dangerous and toxic chemicals can be produced. People are injured or killed. The damage is serious.

Arc fault protection is your insurance against such devastation. The key to total protection is to detect and extinguish the arc immediately. Arc fault protection system will detect an arc anywhere within the switchgear enclosure . A tough, unshielded fibre optic cable is run around the switchgear enclosure’s interior and senses the intense light from a developing arc, no matter where it strikes.
















Readmore → Feeder Fault Protection Module